5 PNEUDRI MiDAS
Service Indication Sequence
& Alarm
During operation, PNEUDRI MiDAS Power On
(yellow) LED and Check (Green) LED indicators
will illuminate, remaining in this configuration for
11500 hours. At this time, the Warning (Yellow)
LED will illuminate and cancel the Check (Green)
LED. This signals the user to order service
replacement components at the optimum time.
500 hours later (a total of 12000 hours from initial
start up) the Service (Red) LED will illuminate and
cancel the Warning (Yellow) LED, the Audible
Alarm housed inside the display will sound
intermittently (every 6 seconds) drawing attention
to the need for a service.
Operation
Compressed air enters the integral pre-filter
and passes into the left hand chamber (Column
A) where the air is dried before passing to the
application.
A small amount of dry purge air is used
to regenerate the right hand chamber (Column
B) which is wet, using the PSA (Pressure Swing
Adsorption) method of regeneration, venting
the saturated air to atmosphere under
pressure. The same regeneration air is also
used to “back flush” the integral filter to
prolong its working life.
1
Prior to changeover, the right hand chamber
(Column B) enters repressurisation where the
exhaust valve is closed to allow pressure to
increase. This process ensures a smooth
uninterrupted changeover, preventing the loss
of any system pressure, before the process
repeats itself.